Accuracy in determining kinetic parameters with force plates embedded under soil-filled baseball mound

(Genauigkeit bei der Bestimmung von Bewegungsparametern mittels einer im Baseballhügel eingebetteten Kraftmessplattform)

We developed a force measurement system embedded in a soil-filled mound for measuring ground reaction forces (GRF) acting on baseball pitchers and examined the accuracy of determining the point of force application (PFA) and kinetic parameters computed from GRF. Three 1.0 x 0.9 m2 force platforms were placed on the concrete foundation of an indoor sports facility and three bays were fixed onto the aluminum plates of the force plateorms. In each tray, clay-blocks were laid tightly and a mixture of red sand and volcanic-ash was used to make a smooth surface layer. The mean absolute error was 6.0 f 4.0 mm in determining PFA, less than 15.5 Ns (5% of the true value) in determining linear impulse. These results suggest that the present method is valid for measuring the PFA and GRF acting on the pitcher's legs for analyzing kinetics of pitching performances.
© Copyright 2016 ISBS - Conference Proceedings Archive (Konstanz). Springer. Veröffentlicht von International Society of Biomechanics in Sports. Alle Rechte vorbehalten.

Schlagworte: Dynamometrie Messplatz Baseball Bewegung Analyse
Notationen: Spielsportarten
Veröffentlicht in: ISBS - Conference Proceedings Archive (Konstanz)
Herausgeber: M. Ae, Y. Enomoto, N. Fujii, H. Takagi
Veröffentlicht: Tsukuba International Society of Biomechanics in Sports 2016
Jahrgang: 34
Heft: 1
Seiten: 129-132
Dokumentenarten: Kongressband, Tagungsbericht
elektronische Zeitschrift
Artikel
Sprache: Englisch
Level: hoch